Commercial & Industrial
Exit Sign Coverage Calculator
Calculate exit sign placement, viewing distance, and code compliance for means-of-egress per NFPA 101, IBC, and IFC. Determines maximum viewing distance based on letter height and minimum illuminance requirements.
Exit Sign Specification
Letter Height 6 in
Sign Type
Mounting Position
Stroke Width Ratio
Corridor / Space Length 100 ft
Ceiling Height 9 ft
Occupancy Load 50 persons
Number of Exits
Coverage & Placement
Max viewing distance—
NFPA 101 formula (100 × letter ht)—
Signs needed for space length—
Recommended spacing—
Min required exits (IBC)—
Illuminance at face—
Battery duration required—
Low-location sign required?—
Self-luminous / photolum OK?—
—
ft max dist
Viewing distance
—
signs needed
For space length
—
fc face
Illuminance
—
min battery
Backup duration
Code Compliance Checklist — NFPA 101 / IBC §1013
Letter height ≥ 6 in (NFPA 101 §7.10.1.2)—
Stroke width ≥ ¾ in (1:5 to 1:10 ratio)—
Internally illuminated ≥ 5 fc (IBC §1013.5)—
Externally illuminated ≥ 5 fc on face—
Emergency power ≥ 90 min (NFPA 101 §7.10.4)—
Continuous operation during normal power—
Visible from any point on egress path—